Jan 28, 2011
Accident
Substantial Buckeye, AZ
Injuries1 minor
Phase of Flight-
ConditionsVMC
OperationFAR 091
Probable Cause
A disconnection of the elevator control linkage due to incorrect installation or maintenance, which was due to the retaining nut backing off the bolt and allowing the bolt to fall out.
NTSB WPR11CA112