Aug 16, 2007
Incident
Minor New Bern, NC
InjuriesNone
Phase of Flight-
ConditionsVMC
OperationFAR 091
Probable Cause
A failure of the stabilator control cable turnbuckle terminal fitting due to corrosion. Contributing to the accident were the mechanic's inadequate annual inspection, and the aircraft manufacturer's failure to provide adequate information in its maintenance manuals regarding the inspection of control cable terminals for corrosion.